FLB Series Light Barriers/Frontends
Frame light barriersGeneral technical data ....
GENERAL TECHNICAL DATA:
Voltage supply | +12VDC ... +32VDC, reserved polarity protected, overload protected with FLB-MSHC-...: +24VDC (±10%), reserved polarity protected, overload protected |
Current consumption | <200mA with FLB-MSHC-...: <350mA |
Max. switching current | 200mA, short-circuit proof with FLB-CIG-...: 100mA, short-circuit proof |
Max. distance transmitter/receiver | depends on sensor type |
Min. detectable object | depends on sensor type |
Illuminant | Infrared |
Optical filter | depends on sensor type |
Ambient light | up to 5000 Lux |
Inputs/outputs | depends on sensor type |
Sensitivity setting | FLB-FK1, FLB-FR1, FLB-F2, FLB-FR3: by means of step switch FLB-CIG: by means of potentiometer |
Pulse lengthening | FLB-FK1, FLB-FR1, FLB-F2, FLB-FR3: by means of step switch |
Dirt accumulation indicator | FLB-FK1, FLB-FR1, FLB-F2: by means of yellow LED and digital output "DIRT" FLB-FR3: by means of yellow LED FLB-CIG: by means of red LED |
Switching state indicator | FLB-FK1, FLB-FR1, FLB-F2, FLB-FR3, FLB-CIG: by means of two-color LED |
Switching frequency (scan frequency) |
depends on sensor type |
Housing dimensions | depends on sensor type |
Housing material | Aluminum, anodized in blue with FLB-CIG-...: Aluminum, anodized |
Type of connector | FLB-F, FLB-H, FLB-V: - to electronic control unit: 8-pole connector Binder 712 FLB-F-...-C, FLB-H-...-C, FLB-V-...-C: - to electronic control unit: --- (no plug) FLB-FK1, FLB-FR1, FLB-F2: - to PLC: 8-pole connector Binder 702 FLB-FR3: - to PLC: 5-pole connector Binder 680 FLB-CIG: - to PLC: 4-pole M8 connector FLB-MSHC-450: - to PLC: 4-pole M12 fem. connector FLB-MSHC-600, FLB-MSHC-1020: - to PLC: 4-pole M12 connector (-T), 8-pol. M12 connector (-R) |
Connecting cables | FLB-F, FLB-H, FLB-V: - to electronic control unit: --- FLB-F-...-C, FLB-H-...-C, FLB-V-...-C: - to electronic control unit: --- FLB-FK1: - to PLC: cab-flb8, cab-flb8/702, cab-flb7/680 or cab-flb8-4/20 FLB-FR1: - to PLC: cab-flb8, cab-flb8/702 or cab-flb7/680 FLB-F2: - for connection of transmitter and receiver: cab-flb-y - to PLC: cab-flb7/680-F2 FLB-FR3: - to PLC: cab-agl5 FLB-CIG: - to PLC: cab-M8/4 FLB-MSHC-...: - to PLC: --- |
Operating temperature range | -20°C ... +50°C (with some types: -20°C ... +60°C) |
Storage temperature range | -20°C ... +60°C (with some types: -20°C ... +85°C) |
Enclosure rating | IP67 |
EMC test acc. to | DIN EN 60947-5-2 |