Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

FLB Series Light Barriers/Frontends

Frame light barriers


General technical data ....

Type IR light curtainMin.
detect.
object
Max. distance transm./ receiverSwitching frequencyInputs/ OutputsFor use with control unitLxWxH (mm) Data
sheet
CAD
data
Appl.
FLB-F-... 5mm ... 100mm (sizes: 05/20 ... 100/100)0.2mm (dep. on size of light curtain)100mmdep. on
control
electronic
used
dep. on control electronic usedFLB-CON1, FLB-CON816x36x5 ... 71x76x5
FLB-H-... 5mm ... 50mm (sizes:
05 ... 50)
0,2mm
(dep. on size of light curtain)
50mmdep. on control electronic useddep. on control electronic usedFLB-CON1, FLB-CON87x20x5 ... 52x20x5
FLB-V-... 5mm ... 100mm (sizes:
05 ... 100)
0.2mm
(dep. on size
of light curtain)
50mmdep. on control electronic useddep. on control electronic usedFLB-CON1, FLB-CON818x11x5 ... 73x11x5
FLB-F-...-C 5mm ... 40mm (sizes: 05/20 ... 40/40)0.2mm (dep. on size of light curtain)40mm10kHz1x STAT,
1x DYN
FLB-CON3-5 (light barrier and electronics assembled)16x36x5 ... 71x76x5
FLB-H-...-C 5mm ... 40mm (sizes:
05 ... 40)
0.2mm (dep. on size of light curtain)30mm10kHz1x STAT,
1x DYN
FLB-CON3-5 (light barrier and electronics assembled)7x20x5 ... 52x20x5
FLB-V-...-C 5mm ... 40mm (sizes:
05 ... 40)
0.2mm (dep. on size of light curtain)30mm10kHz1x STAT,
1x DYN
FLB-CON3-5 (light barrier and electronics assembled)18x11x5 ... 73x11x5
FLB-FK1-.. 38mm ... 300mm (sizes: 38/38 ... 300/300)0.3mm ... 1mm
(dep. on fork size)
300mm1kHzQ, Qinv, Q-ANA, Qinv-ANA---68x83x20 ... 330x345x20
FLB-FR1-.. 38mm ... 300mm (sizes: 38/38 ... 300/300)0,3mm ...
1mm
(dep. on frame size)
300mm1kHzQ, Qinv, Q-ANA, Qinv-ANA---68x83x20 ... 330x345x20
FLB-F2-... 60mm ... 300mm (sizes:
60 ... 300)
0.6mm800mm1kHzQ, Qinv, Q-ANA---60x22.5x20 ... 300x22.5x20
FLB-F2-...-WR 60mm ... 300mm (sizes:
60 ... 300)
0.6mm3000mm1kHzQ, Qinv, Q-ANA---60x22.5x20 ... 300x22.5x20
FLB-F2-...-HS 60mm ... 300mm (sizes:
60 ... 300)
0.6mm800mm10kHzQ, Qinv, Q-ANA---60x22.5x20 ... 300x22.5x20
FLB-FR3-... 58mm ... 198mm (sizes: 58/60 ... 198/200)0.3mm ... 0.7mm200mm1kHzQ, Qinv---74x90x14 ... 214x230x14
FLB-FR3-...-
ANA-HS
58mm ... 198mm (sizes: 58/60 ... 198/200)0.3mm ... 0.7mm200mm10kHzQ, Qinv,
ANA
---74x90x14 ... 214x230x14
FLB-CIG-25L 25mm (paper tear checking/ glue joint detection)Min. detectable error: typ. Ø 3mm of the local defects (holes, dark spots, double sheet))25mm1kHzRESET,
Qinv
---81x60x17
FLB-CIG-25R 25mm (paper tear checking/ glue joint detection)Min. detectable error: typ. Ø 3mm of the local defects (holes, dark spots, double sheet)25mm1kHzRESET,
Qinv
---81x60x17
FLB-CIG-25L-RD 25mm (glue joint detection)Min. detectable error: typ. Ø 3mm of the local defects (dark spots)25mm1kHzRESET,
Qinv
---81x60x17
FLB-CIG-25R-RD 25mm (glue joint detection)Min. detectable error: typ. Ø 3mm of the local defects (dark spots)25mm1kHzRESET,
Qinv
---81x60x17
FLB-MSHC-450 400mm
(24x
IR-LED, screen 16mm)
Resolution: approx. 0.4V (approx. 16mm)180mm50kHz (scan frequency)ANA1,
ANA2
---T+R: 450x20x22
Appl.
FLB-MSHC-600 500mm
(24x
IR-LED, screen 16mm)
Resolution: approx. 0.4V / 0.7mA (approx. 16mm)200mm50kHz (scan frequency)2x ANA (0...10V + 4...20mA)---T+R: 600x46.5x43
FLB-MSHC-1020 950mm
(24x
IR-LED, screen 40mm)
Resolution: approx. 0.4V / 0.7mA (approx. 40mm)200mm50kHz (scan frequency)2x ANA (0...10V + 4...20mA)---T+R: 1032x46.5x43


GENERAL TECHNICAL DATA:
Voltage supply +12VDC ... +32VDC, reserved polarity protected, overload protected
with FLB-MSHC-...:
+24VDC (±10%), reserved polarity protected, overload protected
Current consumption <200mA
with FLB-MSHC-...:
<350mA
Max. switching current 200mA, short-circuit proof
with FLB-CIG-...:
100mA, short-circuit proof
Max. distance transmitter/receiver depends on sensor type
Min. detectable object depends on sensor type
Illuminant Infrared
Optical filter depends on sensor type
Ambient light up to 5000 Lux
Inputs/outputs depends on sensor type
Sensitivity setting FLB-FK1, FLB-FR1, FLB-F2, FLB-FR3:
by means of step switch
FLB-CIG:
by means of potentiometer
Pulse lengthening FLB-FK1, FLB-FR1, FLB-F2, FLB-FR3:
by means of step switch
Dirt accumulation indicator FLB-FK1, FLB-FR1, FLB-F2:
by means of yellow LED and digital output "DIRT"
FLB-FR3:
by means of yellow LED
FLB-CIG:
by means of red LED
Switching state indicator FLB-FK1, FLB-FR1, FLB-F2, FLB-FR3, FLB-CIG:
by means of two-color LED
Switching frequency
(scan frequency)
depends on sensor type
Housing dimensions depends on sensor type
Housing material Aluminum, anodized in blue
with FLB-CIG-...:
Aluminum, anodized
Type of connector FLB-F, FLB-H, FLB-V:
- to electronic control unit: 8-pole connector Binder 712
FLB-F-...-C, FLB-H-...-C, FLB-V-...-C:
- to electronic control unit: --- (no plug)
FLB-FK1, FLB-FR1, FLB-F2:
- to PLC: 8-pole connector Binder 702
FLB-FR3:
- to PLC: 5-pole connector Binder 680
FLB-CIG:
- to PLC: 4-pole M8 connector
FLB-MSHC-450:
- to PLC: 4-pole M12 fem. connector
FLB-MSHC-600, FLB-MSHC-1020:
- to PLC: 4-pole M12 connector (-T), 8-pol. M12 connector (-R)
Connecting cables FLB-F, FLB-H, FLB-V:
- to electronic control unit: ---
FLB-F-...-C, FLB-H-...-C, FLB-V-...-C:
- to electronic control unit: ---
FLB-FK1:
- to PLC: cab-flb8, cab-flb8/702, cab-flb7/680 or cab-flb8-4/20
FLB-FR1:
- to PLC: cab-flb8, cab-flb8/702 or cab-flb7/680
FLB-F2:
- for connection of transmitter and receiver: cab-flb-y
- to PLC: cab-flb7/680-F2
FLB-FR3:
- to PLC: cab-agl5
FLB-CIG:
- to PLC: cab-M8/4
FLB-MSHC-...:
- to PLC: ---
Operating temperature range -20°C ... +50°C (with some types: -20°C ... +60°C)
Storage temperature range -20°C ... +60°C (with some types: -20°C ... +85°C)
Enclosure rating IP67
EMC test acc. to DIN EN 60947-5-2





TOP