L-LAS-LT-HD2 Series
Laser Distance Line Sensors (high dynamic range, detection of dark and bright objects)General technical data ....
GENERAL TECHNICAL DATA:
Software | Windows® PC software: L-LAS-LT-Scope V3.20 SV |
Voltage supply | +24VDC (± 10%), reversed polarity protected, overload protected |
Current consumption | <200mA |
Max. switching current | 100mA, short-circuit proof |
Light source | Semi-conductor laser, 670 nm, <1mW opt. power, DC-operation, Laser class 2 acc. to DIN EN 60825-1:2015-07 (IEC 60825-1:2014) |
Line detector | CCD line detector with 512 pixel, 1024 subpixel |
Measuring range | typ. 85mm (start of measuring range 80mm ... end of measuring range 165mm) |
Resolution | typ. 85µm |
Reproducibility | typ. 0,2%, independent of color |
Linearity | 0,6% FSR (full scale range) |
Laser line geometry | visible laser spot: typ. 0.3mm in focus (= 95mm) |
Optical filter | Interference filter, red light filter |
Analog output | ►with L-LAS-LT-110-HD2-ANA: Voltage 0...+10V, ►with L-LAS-LT-110-HD2-ANA-4/20: Current 4...20mA |
Digital output | OUT0 pnp bright-switching/npn dark-switching or pnp dark-switching/npn bright-switching Output polarity adjustable under Windows® on PC |
Digital input | ►with L-LAS-LT-110-HD2: IN0: External trigger or LASER OFF Input voltage +Ub/0V, with protective circuit |
Laser power correction | adjustable under Windows® on PC |
Temperature stability | 0.01% or measuring range/°C |
LED display | LED green: Operation indicator (power) LED yellow: Switching state indicator |
Scan frequency | typ. 600Hz |
Interface | RS232, parameterizable under Windows® |
Housing dimensions | LxWxH approx. 106mm x 40mm x 50.7mm |
Housing material | Aluminum, anodized in blue |
Type of connector | - to PLC: 4-pole M12-connector - to PC: 5-pole fem. connector Binder 712 |
Connecting cables | - to PLC: cab-M12/4 - to PC: cab-las5/PC, cab-5/USB or cab-5/ETH |
Operating temp. range | -10°C ... +50°C |
Storage temp. range | -20°C ... +85°C |
Enclosure rating | Electronics: IP54, optics: IP67 |
EMC test acc. to | DIN EN 60947-5-2 |