Sensor Instruments
Entwicklungs- und Vertriebs GmbH
Schlinding 15
D-94169 Thurmansbang
Telefon +49 8544 9719-0
Telefax +49 8544 9719-13
info@sensorinstruments.de

TLB-CON Series Electronic Control Units

Amplifiers and Electronic Control Units for Trigger Light Barriers


General technical data ....

Type Operating modeSuitable for
frontend
Max.
switch.
frequency
Inputs/ outputsRS232
inter-
face
LxWxH (mm) Data
sheet
CAD
data
Appl.
TLB-CON1/1 Direct light (DC)FKB-...
FKB-...-BL-...
(cable with open strands is mounted directly to amplifier)
25kHz1xANA OUT
(0...+10V),
2xDIG OUT
(STAT),
2xDIG
(DYN)
no60x27x27
TLB-CON1/2 Direct light (DC)SLB-01-...
SLB-02-...
SLB-03-...
SLB-04-...
SLB-05-...
SLB-06-...
SLB-08-... (cables with open strands are mounted directly to amplifier)
25kHz1xANA OUT
(0...+10V),
2xDIG OUT
(STAT),
2xDIG OUT
(DYN)
no60x27x27
TLB-CON2 Direct light (DC)FKB-...-P
FKB-...-TPN
FKB-...-BL-P
FKB-...-BL-TPN
SLB-...-P
SLB-...-TP
SLB-...-TPN
(connection to amplifier via plug at cable)
25kHz1xANA OUT
(0...+10V),
2xDIG OUT
(STAT),
2xDIG OUT
(DYN)
no65x30x27
TLB-CON2-FIO Direct light (DC)Reflected light or transmitted light fiber optics of FIO Series
(connection to amplifier via fiber optics adaptor)
25kHz1xANA OUT
(0...+10V),
2xDIG OUT
(STAT),
2xDIG OUT
(DYN)
no70x30x27
TLB-CON2-FIO-HAMP Direct light (DC)Reflected light or transmitted light fiber optics of FIO Series
(connection to amplifier via fiber optics adaptor)
high amplification
25kHz1xANA OUT
(0...+10V),
2xDIG OUT
(STAT),
2xDIG OUT
(DYN)
no70x30x27
TLB-CON2-FIO-HS Direct light (DC)Reflected light or transmitted light fiber optics of FIO Series
(connection to amplifier via fiber optics adaptor)
500kHz
(High Speed)
1xANA OUT
(0...+5V),
2xDIG OUT
(Q, Qinv)
no70x30x27
TLB-CON4/1 Direct light (DC)FKB-...
FKB-...-BL-...
(cable with open strands is mounted directly to amplifier)
10kHz2xDIG OUT
(Q, Qinv)
no50x25x25
TLB-CON4/2 Direct light (DC)SLB-01-...
SLB-02-...
SLB-03-...
SLB-04-...
SLB-05-...
SLB-06-...
SLB-08-... (cables with open strands are mounted directly to amplifier)
10kHz2xDIG OUT
(Q, Qinv)
no50x25x25
TLB-CON8-FIO-IR-DC Direct light (DC)
not modulated
Reflected light or transmitted light fiber optics of FIO Series
(connection to amplifier via fiber optics adaptor)
30kHz1xI-CTRL,
1xANA OUT
(0...+10V),
1xDIG OUT
(Digital 0:
0...1V)
Digital 1:
+Ub -10%)
yes60x50x30
TLB-CON11-0/20 Direct light (DC)FKB-...-P
FKB-...-TPN
FKB-...-BL-P
FKB-...-BL-TPN
SLB-...-P
SLB-...-TP
SLB-...-TPN
(connection to amplifier via plug at cable)
Band width analog signal: 200kHz (-3dB)2xANA OUT
Voltage
(0...+10V),
Current
(0mA...20mA)
no65x27x30
TLB-CON11-4/20 Direct light (DC)FKB-...-P
FKB-...-TPN
FKB-...-BL-P
FKB-...-BL-TPN
SLB-...-P
SLB-...-TP
SLB-...-TPN
(connection to amplifier via plug at cable)
Band width analog signal: 200kHz (-3dB)2xANA OUT
Voltage
(0...+10V),
Current
(4mA...20mA)
no65x30x27
TLB-CON11-5/25 Direct light (DC)FKB-...-P
FKB-...-TPN
FKB-...-BL-P
FKB-...-BL-TPN
SLB-...-P
SLB-...-TP
SLB-...-TPN
(connection to amplifier via plug at cable)
Band width analog signal: 200kHz (-3dB)2xANA OUT
Voltage
(0...+10V),
Current
(5mA...250mA)
no65x30x27
TLB-CON11-0/20-FIO Direct light (DC)Reflected light or transmitted light fiber optics of FIO Series
(connection to amplifier via fiber optics adaptor)
Band width analog signal: 200kHz (-3dB)2xANA OUT
Voltage
(0...+10V),
Current
(0mA...20mA)
no70x30x27
TLB-CON11-4/20-FIO Direct light (DC)Reflected light or transmitted light fiber optics of FIO Series
(connection to amplifier via fiber optics adaptor)
Band width analog signal: 200kHz (-3dB)2xANA OUT
Voltage
(0...+10V),
Current
(4mA...20mA)
no70x30x27
TLB-CON11-5/25-FIO Direct light (DC)Reflected light or transmitted light fiber optics of FIO Series
(connection to amplifier via fiber optics adaptor)
Band width analog signal: 200kHz (-3dB)2xANA OUT
Voltage
(0...+10V),
Current
(5mA...25mA)
no70x30x27
TLB-CON3 Alternating light (AC)FKB-...-TPO
FKB-...-BL-TPO
SLB-04-...-TPO
SLB-05-...-TPO
(connection to amplifier via plug at cable)
1kHz1xDIG OUT (Q)no77x30x20
TLB-CON5 Alternating light (AC)FKB-...-P
FKB-...-TPN
FKB-...-BL-P
FKB-...-BL-TPN
SLB-...-P
SLB-...-TP
SLB-...-TPN
(connection to amplifier via plug at cable)
6kHz
(scan-
frequency: 25kHz)
1xI-CTRL,
1xANA OUT
(0...+10V),
1xDIG OUT
(Q / Qinv)
yes60x40x22
TLB-CON5-FIO Alternating light (AC)Reflected light or transmitted light fiber optics of FIO Series
(connection to amplifier via fiber optics adaptor)
6kHz1xI-CTRL,
1xANA OUT
(0...+10V),
1xDIG OUT
(Q / Qinv)
yes65x40x29
TLB-CON8-FIO-IR-AC Alternating light (AC)
modulated
Reflected light or transmitted light fiber optics of FIO Series
(connection to amplifier via fiber optics adaptor)
30kHz1xI-CTRL,
1xANA OUT
(0...+10V),
1xDIG OUT
(Digital 0:
0...1V)
Digital 1:
+Ub -10%)
yes60x50x30
TLB-CON12 Alternating light (AC)FKB-...-P
FKB-...-TPN
FKB-...-BL-P
FKB-...-BL-TPN
SLB-...-P
SLB-...-TP
SLB-...-TPN
(connection to amplifier via plug at cable)
10kHz2xDIG OUT (Q, Qinv)no54x21x26
TLB-CON12-M8 Alternating light (AC)FKB-...-M8
(connection to amplifier via separate cable cab-las4)
10kHz2xDIG OUT (Q, Qinv)no54x21x26


GENERAL TECHNICAL DATA:
Software in case of TLB-CON5, TLB-CON5-FIO:
Windows® PC software: FLB/TLB-Scope
in case of TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
Windows® PC software: FLB/TLB-CON8-Scope
Variants Amplifier or electronic control unit for operation with a sensor frontend of FKB series or SLB series or
in case of TLB-CON...-FIO: for operation with a fiber optics of FIO series
Operation mode depends on type of amplifier:
Direct light operation
(DC) or alternating light operation (AC)
Suitable frontends depends on type of amplifier
Voltage supply +12VDC ... +32VDC, reversed-polarity protected, overload protected
in case of TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
+24VDC (±10%), reversed-polarity protected, overload protected
Current consumption in case of TLB-CON1/1, TLB-CON1/2, TLB-CON2, TLB-CON2-FIO, TLB-CON2-FIO-HAMP:
<80mA
in case of TLB-CON3, TLB-CON4/1, TLB-CON4/2, TLB-CON11-..., TLB-CON11-...-FIO, TLB-CON12, TLB-CON12-M8:
<50mA
in case of TLB-CON2-FIO-HS:
<120mA
in case of TLB-CON5, TLB-CON5-FIO, TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
<150mA
(each including sensor frontend or fiber optics frontend)
Max. switching current in case of TLB-CON1/1, TLB-CON1/2, TLB-CON2, TLB-CON2-FIO, TLB-CON2-FIO-HAMP:
200mA, short-circuit proof
in case of TLB-CON3, TLB-CON4/1, TLB-CON4/2, TLB-CON5, TLB-CON5-FIO, TLB-CON12, TLB-CON12-M18, TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
100mA, short-circuit proof
in case of TLB-CON2-FIO-HS:
Max. output current with pnp-wiring:  2mA
Max. output current with npn-wiring:  10mA
Min. resistance to GND: 10kOhm (in case of pnp-wiring)
Min. resistance to +:        2kOhm (in case of npn-wiring)
Inputs/outputs depends on type of amplifier
Dirt accumulation indication in case of TLB-CON1/1, TLB-CON1/2, TLB-CON2, TLB-CON2-FIO, TLB-CON2-FIO-HAMP, TLB-CON2-FIO-HS, TLB-CON3, TLB-CON11-...-FIO, TLB-CON11-FIO-TLB-CON12, TLB-CON12-M8:
by means of a red LED
Switching state indication
STATISCH
in case of TLB-CON1/1, TLB-CON1/2, TLB-CON2, TLB-CON2-FIO, TLB-CON2-FIO-HAMP, TLB-CON2-FIO-HS, TLB-CON3, TLB-CON4/1, TLB-CON4/2, TLB-CON12, TLB-CON12-M8:
by means of a yellow/green LED
Swit ching state indication
DYNAMIC
in case of TLB-CON1/1, TLB-CON1/2, TLB-CON2, TLB-CON2-FIO, TLB-CON2-FIO-HAMP:
by means of a red/green LED
Operating indication in case of TLB-CON11-..., TLB-CON11-...-FIO:
by means of a green LED
Pulse lengthening in case of TLB-CON5, TLB-CON5-FIO, TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
adjustable under Windows® via PC
Sensitivity (gain) in case of TLB-CON1/1, TLB-CON1/2, TLB-CON2-FIO, TLB-CON2-FIO-HAMP, TLB-CON2-FIO-HS, TLB-CON3, TLB-CON4/1, TLB-CON4/2, TLB-CON11-..., TLB-CON11-...-FIO, TLB-CON12, TLB-CON12-M8:
adjustable by means of potentiometer
bei TLB-CON5, TLB-CON5-FIO, TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
adjustable under Windows® via PC
Trigger threshold in case of TLB-CON1/1, TLB-CON1/2, TLB-CON2, TLB-CON2-FIO, TLB-CON2-FIO-HAMP, TLB-CON2-FIO-HS,
adjustable by means of potentiometer
Threshold correction in case of TLB-CON1/1, TLB-CON1/2, TLB-CON2, TLB-CON2-FIO, TLB-CON2-FIO-HAMP
adjustable by means of integrated jumper
in case of TLB-CON5, TLB-CON5-FIO, TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
adjustable under Windows® via PC
Switching frequency depends on type of amplifier
Scan frequency depends on type of amplifier
Band width analog signal depends on type of amplifier
Interface in case of TLB-CON5, TLB-CON5-FIO, TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
RS232, parameterisable under Windows® via PC
Housing dimensions depends on type of amplifier
Housing material Aluminum, anodized in blue
Type of connector depends on type of amplifier:
in case of TLB-CON1/1, TLB-CON1/2
- to PLC: 7-pole connector Binder 680
- to sensor frontend: ---
in case of TLB-CON2, TLB-CON11-...,
- to PLC: 8-pole connector Binder 712
- to sensor frontend: 8-pole fem. connector Binder 712
in case of TLB-CON3:
- to PLC: 5-pole connector Binder 680
- to sensor frontend: 5-pole fem. connector Binder 680
in case of TLB-CON4/1, TLB-CON4/2
- to PLC: 5-pole connector Binder 680
- to sensor frontend: ---
in case of TLB-CON5:
- to PLC: 4-pole M8-connector
- to PC: 5-pole fem. connector Binder 712
- to sensor frontend: 8-pole fem. connector Binder 712
in case of TLB-CON12:
- to PLC: 5-pole M12-connector
- to sensor frontend: 8-pole fem. connector Binder 712
in case of TLB-CON12-M8:
- to PLC: 5-pole M12-connector
- to sensor frontend: 4-pole M8-connector
in case of TLB-CON2-FIO, TLB-CON2-FIO-HAMP, TLB-CON2-FIO-HS
- to PLC: 8-pole connector Binder 712
- to optical frontend: fiber optics adapter for fiber optics of FIO series
in case of TLB-CON5-FIO:
- to PLC: 4-pole M8-connector
- to PC: 5-pole fem. connector Binder 712
- to optical frontend: fiber optics adapter for fiber optics of FIO series
in case of TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
- to PLC: 8-pole connector Binder 712
- to PC: 5-pole fem. connector Binder 712
- to optical frontend: fiber optics adapter for fiber optics of FIO series
in case of TLB-CON11-...-FIO:
- to PLC: 8-pole connector Binder 712
- to optical frontend: fiber optics adapter for fiber optics of FIO series
Connecting cable in case of TLB-CON1/1, TLB-CON1/2:
- to PLC: cab-las-agl7
- to sensor frontend: ---
in case of TLB-CON2, TLB-CON11-...:
- to PLC: cab-las8/702-fem
- to sensor frontend: (only in case of -TP or -TPN) cab-tlb8/702
in case of TLB-CON3:
- to PLC: SI-KAB2 or cab-agl5
in case of TLB-CON4/1, TLB-CON4/2:
- to PLC: cab-agl5
- to sensor frontend: ---
in case of TLB-CON5:
- to PLC: cab-M8/4
- to PC: cab-las5/PC, cab-5/USB or cab-5/ETH
- to sensor frontend: (only in case of -TP or -TPN) cab-tlb8/702
in case of TLB-CON12:
- to PLC: cab-M12/5-g-2-shd
- to sensor frontend: (only in case of -TP or -TPN) cab-tlb8/702
in case of TLB-CON12-M8:
- to PLC: cab-M12/5-g-2-shd
- to sensor frontend: cab-las4
in case of TLB-CON2-FIO, TLB-CON2-FIO-HAMP, TLB-CON2-FIO-HS
- to PLC: cab-las8/702-fem
- to optical frontend: ---
in case of TLB-CON5-FIO:
- to PLC: cab-M8/4
- to PC: cab-las5/PC, cab-5/USB or cab-5/ETH
- to optical frontend: ---
in case of TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
- to PLC: cab-las8/702-fem
- to PC: cab-las5/PC, cab-5/USB or cab-5/ETH
- to optical frontend: ---
in case of TLB-CON11-...-FIO:
- to PLC: cab-las8/702-fem
- to optical frontend: ---
Operating temp. range -20°C ... +60°C
in case of TLB-CON3, TLB-CON12, TLB-CON12-M8:
-20°C ... +70°C
in case of TLB-CON8-FIO-IR-AC, TLB-CON8-FIO-IR-DC:
-20°C ... +55°C
Storage temp. range -20°C ... +85°C
Enclosure rating IP64
in case of TLB-CON3, TLB-CON12, TLB-CON12-M8:
IP67
EMC test acc. to DIN EN 60947-5-2