FLB-CON Series Electronic control units

Electronic control units for frame light barriers


General technical data ....

Type Suitable for frontendMin. detect. objectSwitching frequencyInputs/ outputsRS232 inter- faceLxWxH (mm) Data
sheet
CAD
data
Appl.
FLB-CON1-Q FLB-F-..., FLB-H-..., FLB-V, FKB-...-P, SLB-...-P0.05mm1kHzDYN---70x36x24
FLB-CON1-Qinv FLB-F-..., FLB-H-..., FLB-V, FKB-...-P, SLB-...-P0.05mm1kHzINV DYN---70x36x24
FLB-CON1-Q-ANA FLB-F-..., FLB-H-..., FLB-V, FKB-...-P, SLB-...-P0.05mm1kHzDYN, ANA (0...10V)---70x36x24
FLB-CON1-Qinv-ANA FLB-F-..., FLB-H-..., FLB-V, FKB-...-P, SLB-...-P0.05mm1kHzINV DYN, ANA (0...10V)---70x36x24
FLB-CON1-Q-15kHz FLB-F-..., FLB-H-..., FLB-V, FKB-...-P, SLB-...-P0.05mm15kHzDYN---70x36x24
FLB-CON1-Qinv-15kHz FLB-F-..., FLB-H-..., FLB-V, FKB-...-P, SLB-...-P0.05mm15kHzINV DYN---70x36x24
FLB-CON1-Q-ANA-15kHz FLB-F-..., FLB-H-..., FLB-V, FKB-...-P, SLB-...-P0.05mm15kHzDYN, ANA (0...10V)---70x36x24
FLB-CON1-Qinv-ANA-15kHz FLB-F-..., FLB-H-..., FLB-V, FKB-...-P, SLB-...-P0.05mm15kHzINV DYN, ANA (0...10V)---70x36x24
FLB-CON2-2X FLB-F-..., FLB-H-..., FLB-V, FKB-...-P, SLB-...-P0.05mm6kHz2x DIG: TOL1, TOL2Windows® PC-Software FLB/TLB- 2X-V1.0- Scope60x40x22
FLB-CON3-5 FLB-F-...-C, FLB-H-...-C, FLB-V-C0.2mm10kHzSTAT, DYN---60x27x27
FLB-CON8-AC FLB-F-..., FLB-H-..., FLB-V-..., FKB-...-P, SLB-...-P0.05mm30kHz (scan frequency 200kHz)Ext. teach input (+24VDC/0V), DIG (OUT0), ANA (0...10V)Windows® PC software FLB-TLB-
CON8-Scope
60x50x22
FLB-CON8-DC FLB-F-..., FLB-H-..., FLB-V-..., FKB-...-P, SLB-...-P0.05mm30kHz (scan frequency 200kHz)Ext. teach input (+24VDC/0V), OUT0, ANA (0...10V)Windows® PC software FLB-TLB-
CON8-Scope
60x50x22


GENERAL TECHNICAL DATA:
Software with FLB-CON2-2X:
Windows® PC software: FLB/TLB-2X-V1.0-Scope
with FLB-CON8-AC, FLB-CON8:
Windows® PC software: FLB-TLB-CON8-Scope
Voltage supply +12VDC ... +32VDC, reversed polarity protected, overload protected
with FLB-CON8-AC, FLB-CON8-DC:
+24VDC (±10%), reversed polarity protected, overload protected
Current consumption with sensor frontend: <80mA
Max. switching current 200mA, short-circuit proof
Inputs/outputs depends on sensor type
Suitable sensor frontends depends on sensor type
Dirt accumulation indicator with FLB-CON1, FLB-CON1-15kHz, FLB-CON3-5:
by means of LED
Switching state indicator with FLB-CON1, FLB-CON1-15kHz, FLB-F2-2X, FLB-CON3-5:
by means of LED
Pulse lengthening with FLB-CON1, FLB-CON1-15kHz, FLB-CON3-5:
by means of step switch
with FLB-F2-2X, FLB-CON8-AC, FLB-CON8-DC:
via software
Sensitivity setting with FLB-CON1, FLB-CON1-15kHz:
by means of step switch
with FLB-CON3-5:
by means of potentiometer
with FLB-F2-2X, FLB-CON8-AC, FLB-CON8-DC:
via software
Adjustment of
trigger threshold
with FLB-CON3-5:
by means of potentiometer
Threshold correction with FLB-CON3-5:
by means of integrated  jumper
Switching frequency depends on sensor type
Interface with FLB-CON2-2X, FLB-CON8-AC, FLB-CON8-DC:
RS232, parameterizable under Windows® on PC
Housing dimensions depends on sensor type
Housing material Aluminum, anodized in blue
Type of connector depends on sensor type:
FLB-CON1, FLB-CON1-15kHz:
- to PLC: 4-pole M8-connector
- to sensor frontend: 8-pole fem. connector Binder 712
FLB-CON2-2X:
- to PLC: 4-pole M8-connector
- to PC: 5-pole Buchse Binder 712
- to sensor frontend: 8-pole fem. connector Binder 712
FLB-CON3-5:
- tp PLC: 5-pole connector Binder 680
FLB-CON8-AC, FLB-CON8-DC:
- to PLC: 8-pole connector Binder 712
- to PC: 5-pole fem. connector Binder 712
- to sensor frontend: 8-pole fem. connector Binder 712
Connecting cables depends on sensor type:
FLB-CON1, FLB-CON1-15kHz:
- to PLC: cab-M8/4
FLB-CON2-2X:
- to PLC: cab-M8/4
- to PC: cab-las5/PC or cab-5/USB
FLB-CON3-5:
- to PLC: cab-agl5
FLB-CON8-AC, FLB-CON8-DC:
- to PLC: cab-las8/702-fem
- to PC: cab-las5/PC, cab-5/USB or cab-5/ETH
Operating temperature range -20°C ... +60°C
Storage temperature range -20°C ... +85°C
Enclosure rating IP64
EMC test acc. to DIN EN 60947-5-2