Software news


Here you will find news regarding our sensor software as well as software updates:


Select language:



Color control and color measurement

N° 30
Version SPECTRO2-Scope V1.8

Manual
Changes


Changes after Software Update from SPECTRO2-Scope V1.7 to V1.8
Change 1:
THRESHOLD MODE = 2 TRSH has been renamed to 2 TRSH SIG.
The evaluation has remained the same.

THRESHOLD MODE = 2 TRSH SIG:
2 switching thresholds are available in this mode.
Switching threshold1(2) = REF1(2) – TOLERANCE 1(2)
Hysteresis threshold1(2) = REF1(2) – HYSTERESIS 1(2)

Change 2:
THRESHOLD MODE = 2 TRSH CH was implemented.

THRESHOLD MODE = 2 TRSH CH:
Two switching thresholds are also available in this mode.
Switching threshold1(2) = REF1(2) – TOLERANCE 1(2)
Hysteresis threshold1(2) = REF1(2) – HYSTERESIS 1(2)
In contrast to 2 TRSH SIG, SIG will not be evaluated here, but CH0 and CH1.

Change 3:
OPERATING MODE = DELTA CH SIG INTEGRATOR was implemented.

With DELTA CH SIG INTEGRATOR the deviation of CH SIG from a reference value for CH SIG (REF VAL CH SIG) is determined, standardized to 4096 and added with 2048.
CH SIG: result of the calculation method set under EVALUTION MODE.

Color control and color measurement

N° 29
Version SPECTRO3-MSM-SLE-Scope V1.2

Manual
Changes


Changes after Software Update from SPECTRO3-MSM-SLE-Scope V1.1 to V1.2
Change 1:
SET DP:
If an application involves both very bright and very dark surfaces, and the sensor is set such that it is not in saturation at the bright surfaces, the dark surfaces frequently provide only a very low signal.
Little variations with a very low signal lead to a large change in color space calculation (C-SPACE). To minimise this effect, the sensor in PMODE = DOUBLE automatically switches back and forth between 2 DOUBLE PARAMETER sets. Set 2 must be parameterised such that the signal is maximally amplified.
When the signal is too high (saturation), it automatically switches to set 1.
To get correct color space coordinates with set 2, a correction factor must be used for the signal.
The two DOUBLE PARA

Change 2:
With START CALIBRATION ASSISTANT you can start an assistant that guides you through the calibration.
The following three conditions must be met:
1. You need one reference card. This is either the card RAL 9003-P, RAL 9010-P, or RAL 9016-P.
2. You need different RAL colors RAL from the RAL CLASSIC or RAL DESIGN SYSTEM plus series. These are available from the sensor supplier.
3. You need a file in which the L*a*b* values for the different RAL cards are stored. This file is also available from the supplier.

Color control and color measurement

N° 28
Version SPECTRO3-MSM-SLA-Scope V1.2

Manual
Changes


Changes after Software Update from SPECTRO3-MSM-SLA-Scope V1.1 to V1.2
Change 1:
SET DP:
If an application involves both very bright and very dark surfaces, and the sensor is set such that it is not in saturation at the bright surfaces, the dark surfaces frequently provide only a very low signal.
Little variations with a very low signal lead to a large change in color space calculation (C-SPACE). To minimise this effect, the sensor in PMODE = DOUBLE automatically switches back and forth between 2 DOUBLE PARAMETER sets. Set 2 must be parameterised such that the signal is maximally amplified.
When the signal is too high (saturation), it automatically switches to set 1.
To get correct color space coordinates with set 2, a correction factor must be used for the signal.
The two DOUBLE PARA

Change 2:
With START CALIBRATION ASSISTANT you can start an assistant that guides you through the calibration.
The following three conditions must be met:
1. You need one reference card. This is either the card RAL 9003-P, RAL 9010-P, or RAL 9016-P.
2. You need different RAL colors RAL from the RAL CLASSIC or RAL DESIGN SYSTEM plus series. These are available from the sensor supplier.
3. You need a file in which the L*a*b* values for the different RAL cards are stored. This file is also available from the supplier.

Color control and color measurement

N° 27
Version SPECTRO3-MSM-DIG-Scope V1.5 (V1.5.1)

Manual
Changes


Changes after Software Update from SPECTRO3-MSM-DIG-Scope V1.4 to V1.5
Change 1:
SET DP:
If an application involves both very bright and very dark surfaces, and the sensor is set such that it is not in saturation at the bright surfaces, the dark surfaces frequently provide only a very low signal.
Little variations with a very low signal lead to a large change in color space calculation (C-SPACE). To minimise this effect, the sensor in PMODE = DOUBLE automatically switches back and forth between 2 DOUBLE PARAMETER sets. Set 2 must be parameterised such that the signal is maximally amplified.
When the signal is too high (saturation), it automatically switches to set 1.
To get correct color space coordinates with set 2, a correction factor must be used for the signal.
The two DOUBLE PARA

Change 2:
With START CALIBRATION ASSISTANT you can start an assistant that guides you through the calibration.
The following three conditions must be met:
1. You need one reference card. This is either the card RAL 9003-P, RAL 9010-P, or RAL 9016-P.
2. You need different RAL colors RAL from the RAL CLASSIC or RAL DESIGN SYSTEM plus series. These are available from the sensor supplier.
3. You need a file in which the L*a*b* values for the different RAL cards are stored. This file is also available from the supplier.

Color control and color measurement

N° 26
Version SPECTRO3-MSM-ANA-Scope V3.3 (V3.3.1)

Manual
Changes


Changes after Software Update from SPECTRO3-MSM-ANA-Scope V3.2 to V3.3
Change 1:
SET DP:
If an application involves both very bright and very dark surfaces, and the sensor is set such that it is not in saturation at the bright surfaces, the dark surfaces frequently provide only a very low signal.
Little variations with a very low signal lead to a large change in color space calculation (C-SPACE). To minimise this effect, the sensor in PMODE = DOUBLE automatically switches back and forth between 2 DOUBLE PARAMETER sets. Set 2 must be parameterised such that the signal is maximally amplified.
When the signal is too high (saturation), it automatically switches to set 1.
To get correct color space coordinates with set 2, a correction factor must be used for the signal.
The two DOUBLE PARAMETER sets must be set at the sensor in advance.
When you click on SET DP (Set Double Parameter) a window will open at the right side, where you can set two sets. A Double Parameter set is defined by POWER, GAIN and INTEGRAL.

Change 2:
With START CALIBRATION ASSISTANT you can start an assistant that guides you through the calibration.
The following three conditions must be met:
1. You need one reference card. This is either the card RAL 9003-P, RAL 9010-P, or RAL 9016-P.
2. You need different RAL colors RAL from the RAL CLASSIC or RAL DESIGN SYSTEM plus series. These are available from the sensor supplier.
3. You need a file in which the L*a*b* values for the different RAL cards are stored. This file is also available from the supplier.

Color control and color measurement

N° 25
Version SPECTRO3-MSM-DIG-Scope V1.5 (V1.5.0)

Manual
Changes


Changes after Software Update from SPECTRO3-MSM-DIG-Scope V1.4 to V1.5
There is only one extension in DOUBLE mode:
If an application involves both very bright and very dark surfaces, and the sensor is set such that it is not in saturation at the bright surfaces, the dark surfaces frequently provide only a very low signal.
Little variations with a very low signal lead to a large change in color space calculation (C-SPACE). To minimise this effect, the sensor in PMODE = DOUBLE automatically switches back and forth between 2 DOUBLE PARAMETER sets. Set 2 must be parameterised such that the signal is maximally amplified.
When the signal is too high (saturation), it automatically switches to set 1.
To get correct color space coordinates with set 2, a correction factor must be used for the signal.
The two DOUBLE PARAMETER sets must be set at the sensor in advance.
When you click on SET DP (Set Double Parameter) a window will open at the right side, where you can set two sets. A Double Parameter set is defined by POWER, GAIN and INTEGRAL.

Color control and color measurement

N° 24
Version SPECTRO3-MSM-ANA-Scope V3.3 (V3.3.0)

Manual
Changes


Changes after Software Update from SPECTRO3-MSM-ANA-Scope V3.2 to V3.3
There is only one extension in DOUBLE mode:
If an application involves both very bright and very dark surfaces, and the sensor is set such that it is not in saturation at the bright surfaces, the dark surfaces frequently provide only a very low signal.
Little variations with a very low signal lead to a large change in color space calculation (C-SPACE). To minimise this effect, the sensor in PMODE = DOUBLE automatically switches back and forth between 2 DOUBLE PARAMETER sets. Set 2 must be parameterised such that the signal is maximally amplified.
When the signal is too high (saturation), it automatically switches to set 1.
To get correct color space coordinates with set 2, a correction factor must be used for the signal.
The two DOUBLE PARAMETER sets must be set at the sensor in advance.
When you click on SET DP (Set Double Parameter) a window will open at the right side, where you can set two sets. A Double Parameter set is defined by POWER, GAIN and INTEGRAL.


Color control and color measurement

N° 23
Version SPECTRO2-Scope V1.7

Manual
Changes


Changes after Software Update from SPECTRO2-Scope V1.6 to V1.7
1) The newly added LED SAT indicates if one of the channels CH0 or CH1 is in saturation. If this is the case, it lights up red. This is very helpful when e.g. working with LED MODE = AC.

2) In the CONVERSION TABLE on the tab CONVERSION, the COMMENT column has been added. An individual comment for every line can be entered in the COMMENT column.

3) With the sensors of the SPECTRO-2 series a channel balancing can be performed. The balancing can be performed on any surface. Channel balancing makes sense given multiple sensors which are to be taught.

Color control and color measurement

N° 22
Version SPECTRO1-Scope V3.1

Manual
Changes


Changes after Software Update from SPECTRO1-Scope V3.0 to V3.1
1) OPERATING MODE = DELTA CH0 INTEGRATOR has been added.

2) The display SIG was introduced to improve understanding.

3) In addition to CH0, the signal value SIG is transferred in the SCOPE tab.

Color control and color measurement

N° 21
Version V2.0.0

Manual
Changes


SPECTRO3-ANA-Scope V2.0 (2017.06.13)
Color control and color measurement

N° 20
Version V1.2.0

Manual
Changes


SPECTRO3-MSM-DIG-Scope V1.2 (2017.06.06)
Color control and color measurement

N° 19
Version V3.0.0

Manual
Changes


SPECTRO3-MSM-ANA-Scope V3.0 (2017.06.06)
Color control and color measurement

N° 18
Version V2.9.0

Manual
Changes


SPECTRO3-MSM-ANA-Scope V2.9 (2017.06.06)
Surface inspection and gloss measurement

N° 17
Version V2.2.1



STRUCT-Scope V2.2 (2017.05.04)
Fiber optics and accessories

N° 16
Version V1.1.2

Manual


SensorFinder V1.1 (2017.04.13)
Color control and color measurement

N° 15
Version V1.0.0

Manual


SPECTRO1-SC-Scope V1.0 (2017.03.30)
Color control and color measurement

N° 14
Version V1.1.3

Manual
Changes


SPECTRO3-SLE-Scope V1.1 (2017.02.08)
Color control and color measurement

N° 13
Version V1.3.3

Manual
Changes


SPECTRO3-SL-Scope V1.3 (2017.02.08)
Color control and color measurement

N° 12
Version V1.4.4

Changes


SPECTRO3-ANA-Scope V1.4 (2017.02.08)
Color control and color measurement

N° 11
Version V1.1.1

Changes


SPECTRO3-MSM-DIG-Scope V1.1 (2017.02.08)
Color control and color measurement

N° 10
Version V2.8.1

Changes


SPECTRO3-MSM-ANA-Scope V2.8 (2017.02.08)
Color control and color measurement

N° 9
Version V4.4.5

Changes


SPECTRO3-Scope V4.4 (2017.02.08)
Color control and color measurement

N° 8
Version V1.4.1

Changes


SPECTRO2-Scope V1.4 (2017.02.08)
Color control and color measurement

N° 7
Version V2.8.1

Changes


SPECTRO1-Scope V2.8 (2017.02.08)
Surface inspection and gloss measurement

N° 6
Version V2.1.1



STRUCT-Scope V2.1 (2016.12.02)
Distance measurement and positioning

N° 5
Version V4.0.5



L-LAS-TB-Scope V4.0 (2016.11.28)
Color control and color measurement

N° 4
Version V2.7.1

Changes


SPECTRO1-Scope V2.7 (2016.10.24)
Color control and color measurement

N° 3
Version V1.3.0

Changes


SPECTRO2-Scope V1.3 (2016.10.19)
Color control and color measurement

N° 2
Version V1.0.0



Digital Output Control V1.0 (2016.10.19)
Surface inspection and gloss measurement

N° 1
Version V2.0.5

Changes


STRUCT-Scope V2.0 (2016.07.15)
The structure detection software STRUCT-Scope software is now also available for the L-LAS-RL-CL series. The software automatically detects whether a COAST, GLAST or L-LAS-RL-CL sensor is connected.
A new evaluation mode VIDEOLENGTH / 256 has been inserted. In this case, the length of the video signal is viewed and used as a further parameter for evaluation.



NEWS

Participation at trade fairs:

 •   AIMEX Automation World 2024
 •   IFAT Munich 2024
 •   FIP 2024
 •   PRS Europe 2024
 •   SKZ Innovation Day Recycling
 
•   SKZ Network Day
 •   SKZ Technology Day
 •   PRS Middle East & Africa 2024
 •   Plastics Recycling World Expo
     
Europe 2024
 •   Plastics Recycling World Expo
     
North America 2024
 •   PRS Asia 2024
 •   PRS India 2024

more...


Press releases:

Inline color calibration with respect to plastic recyclate
(Inline color measurement systems)

 
Test report on Inline color measurement of recyclates
(Inline color measurement system)

more...


Whitepapers:

Sensor systems for recyclate control in the plastics industry for laboratory and inline use
Checking the plastic type of recyclates and virgin material using NIR technology

more...


A
pplications:


Detection of dents and bumps on metal punching strips
(N° 801)
Differentiation of leather, fabric and synthetic interior components
(N° 802)
Plastic cap color measurement
(N° 803)

more...


WHAT IS ...
... surface tension?
... oil evaporation?
... oil layer thickness
    measurement?

more...


Software news:

SPECTRO3-MSM-DIG-Scope V1.5 (2021.10.20)
V1.5.2

more...




FIND US ON ....

Facebook X (Twitter) Instagram Youtube in

 








TOP