1) Select field of application:
    Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik)


2) Select language:


Data
sheet:


APP N° 662

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
Ultra-low spray jet control
The presence as well as the density of an ultra-low spray jet should be controlled.
Data
sheet:


APP N° 535

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
INI:
Color mark control on syringes
The color of the mark on syringes should be controlled.
Data
sheet:


APP N° 512

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
INI:
Hole presence control on catheter tubes
The presence of holes on catheter tubes should be controlled.
Data
sheet:


APP N° 511

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
INI:
Catheter dome presence control
The presence of a dome at the end of a catheter should be controlled.
Data
sheet:


APP N° 451

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Position monitoring of a rubber plug before the final positioning in a syringe
The position of a rubber plug should be controlled with regard to the outer face and inner surface.
Data
sheet:


APP N° 447

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Param.:
INI:
Color differentiation of plastic caps for syringes
Plastic caps used for syringes should be color controlled. It has to be taken into account, that the plastic caps are semitransparent and the surface is very glossy.
Data
sheet:


APP N° 319

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Differentiation of coated and uncoated syringes
Coated syringes should be distinguished from uncoated syringes.
Data
sheet:


APP N° 310

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detection of a gap on adhesive plaster
The presence of a gap of the tape on an adhesive plaster should be detected.
Data
sheet:


APP N° 308

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Presence control of plaster in a transparent plastic bag
The presence of plaster in a transparent plastic bag should be controlled. At this, a part of the plaster is fluorescent if UV light is used.
Data
sheet:


APP N° 294

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Thickness control of shiny aluminum cushions
The thickness of different shiny aluminum cushions should be measured. These aluminum cushions are used for heat insulation. At this, the cushions will be transported on a conveyor belt with a very small fluctuation in height, thus the distance to the belt can be used as a reference.
Data
sheet:


APP N° 270

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Differentiation of front- and backside of a fleece
The front side of a fleece should be differentiated from the back side. The back side (non structured side) is UV fluorescent, whereas the plastic structured film is nonfluorescent and damps the fluorescence.
Data
sheet:


APP N° 266

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detection of the section point on black nonmetallic strapping
The section point on a shiny black nonmetallic strapping should be detected optically in the reflective way.
Data
sheet:


APP N° 257

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detection of transparent coating on rubber seals
The coating of rubber seals should be detected. At this, different types should be controlled with the same sensor, thus the spot size of the sensor must fit to the smallest rubber size and should of course deliver proper results from the bigger seals, too.
Data
sheet:


APP N° 252

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Cutoff point detection of white nonmetallic strapping
The cutoff point of white nonmetallic strapping should be detected in a reflective way.
Data
sheet:


APP N° 222

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Sleeve presence control on an injection needle
The presence of a sleeve on an injection needle should be controlled.
Data
sheet:


APP N° 207

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detection of a gap between successive hygiene articles during the transportation in a conveyor belt
Panty liners will be transported between two belts. The beginning as well as the end of a panty liner should be detected. Furthermore, a gap between two successive panty liners should be detected. The only practicable possibility is to look through the two conveyor belts.
Data
sheet:


APP N° 203

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Presence control of the sleeve on an injection needle
The presence of a sleeve should be controlled.
Data
sheet:


APP N° 198

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Color control of blood in a laboratory glass
Blood in a laboratory glass with different liquid level should be color controlled.
Data
sheet:


APP N° 184

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Double layer control of fleece material
It should be differentiated between one and two layers of a fleece material.
Data
sheet:


APP N° 162

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Presence control of a label on a nursing pad
The presence of a label on a nursing pad should be controlled.
Data
sheet:


APP N° 147

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Position control of a thread on a tampon
The right position of a thread on the backside of a tampon should be controlled. Right position means in this case, that the cyan colored thread should cover nearly the whole backside of the tampon. The position of the thread must be checked through a transparent plastic film.
Data
sheet:


APP N° 143

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Position monitoring of hook-and-loop fasteners
The orientation of Velcro® fasteners should be controlled.
Data
sheet:


APP N° 111

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Drop control with a laser through beam system
The number as well as the volume of drops should be controlled.
Data
sheet:


APP N° 105

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Spray jet amount control
The density of the spray jet should be controlled.
Data
sheet:


APP N° 92

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Color differentiation of syringe capsules
Syringe capsules must be color differentiated. At this, there should be detected also an unacceptable color change from batch to batch of the same capsule type.
Data
sheet:


APP N° 25

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detekcija oz. razpoznava barvne oznake na plenicah za enkratno uporabo
Oznake različnih barv lahko zaznamo in ločujemo z linijskim senzorjem. Največja produkcijske hitrost je 10 m/s.

Detection of color marks on disposal diapers
Different color marks (different in color) should be detected with an inline sensor. The maximum production speed is 10 m/s.
Data
sheet:


APP N° 11

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Zaznava vzporednosti in prisotnosti bele nalepke na belih plenicah
Med proizvodnjo plenic je potrebno preveriti prisotnost in položaj nalepke / zavihka.

Inline edge detection of a white label on a white diaper
During the assembly of diapers, the presence as well as the position of the label must be controlled.
Data
sheet:


APP N° 4

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detection of the presence of the fleece during the production of disposable diapers
During the production of disposable diapers the assembling of the fleece must be checked. The production speed is approximately up to 10m/s and the height of the diapers can slightly changing. Furthermore the color of the diaper as well as the color of the fleece is white but additionally to this the fleece is fluorescent in blue under the influence of UV light.
Data
sheet:


APP N° 3

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Detekcija pravilne smeri laminiranega traku (prednja / zadnja stran)
Potrebno je kontrolirati smer laminiranega traku (Gore laminated band). Barva traku je lahko bela, črna ali rdeča.

Detection of the correct direction of a laminated band (front side/back side detection)
The direction of a laminated band (Gore laminated band) must be controlled. The color of the band can be white, black or red.
Data
sheet:


APP N° 2

Medical Technology / Hygienic Technology (Medizintechnik / Hygienetechnik) 
Hook-and-pile fastener (Velcro®) direction control
The task is to check the direction of the hook-and-pile fastener.


NEWS

Participation at trade fairs:

 
•   IFAT Munich 2024
 •   SPS Italia 2024
 •   FIP 2024
 •   PRS Europe 2024
 •   SKZ Innovation Day Recycling
 
•   SKZ Network Day
 •   SKZ Technology Day
 •   PRS Middle East & Africa 2024
 •   Plastics Recycling World Expo
     
Europe 2024
 •   Plastics Recycling World Expo
     
North America 2024
 •   PRS Asia 2024
 •   PRS India 2024
 •   European Coatings Show 2025

more...


Specialists article:

  Testing Recyclates Directly during Injection Molding and Extrusion
NIR Process for the Inline Inspection of Recycled Plastics
PlasticsInsights 3/2024

 

more...


Press releases:

Inline color calibration with respect to plastic recyclate
(Inline color measurement systems)

 
Test report on Inline color measurement of recyclates
(Inline color measurement system)

more...


Whitepapers:

Sensor systems for recyclate control in the plastics industry for laboratory and inline use
Checking the plastic type of recyclates and virgin material using NIR technology

more...


A
pplications:


Detection of dents and bumps on metal punching strips
(N° 801)
Differentiation of leather, fabric and synthetic interior components
(N° 802)
Plastic cap color measurement
(N° 803)

more...


WHAT IS ...
... surface tension?
... oil evaporation?
... oil layer thickness
    measurement?

more...


Software news:

SPECTRO3-MSM-DIG-Scope V1.5 (2021.10.20)
V1.5.2

more...




FIND US ON ....

Facebook X (Twitter) Instagram Youtube in

 








TOP